All structures assessed PI 1226 (A72) – Andrézieux-Bouthéon (VC 6) Structure studied for an abnormal-load convoy of 76.338 tonnes. The PICF (single closed frame) has a 10.00 m opening for a 10.50 m span. Bending moments in the deck under the convoy studied.