Checking of a reinforced concrete beam for shear and torsion, to EN 1992-1-1 and its French National Annex: shear alone, torsion with its interaction, or both combined.

The sheet applies the French National Annex: its interface and the PDF calculation note are in French.

How to use

  • Choose the case studied (“Cas étudié”); common data (materials, shear force, dimensions) are carried over from one case to another.
  • Shear: web width, effective depth, tensile longitudinal reinforcement (ratio ρl), links (diameter, number of legs, spacing), axial force if any and strut angle.
  • Torsion: rectangular section, cover, longitudinal bars around the perimeter and closed links; the concurrent shear force is used for the interaction.
  • Combined shear and torsion: rectangular or T section, with axial force if any.
  • “Calculer” gives the verdict, the utilisation ratio of each criterion and suggestions; the PDF calculation note can be downloaded below the results.

Assumptions

  • French National Annex (March 2016): CRd,c = 0.18/γc, vmin according to the member type, 1 ≤ cot θ ≤ 2.5 (reduced bounds in tension, 6.7bNF); an angle outside the bounds is brought back to the bound. γc = 1.5; γs = 1.15.
  • Vertical shear reinforcement; lever arm z = 0.9·d; σcp = NEd/Ac, limited to 0.2·fcd.
  • Torsion: equivalent thin-walled section (§6.3.2), thickness tef = A/u with a minimum related to the cover; interaction TEd/TRd,max + VEd/VRd,max ≤ 1.
  • Torsion reinforcement is added to shear and bending reinforcement; detailing rules (§9.2) remain to be checked.

Example

Beam, 30 × 60 cm, near a support, C30/37, HA8 links every 15 cm, under VEd = 150 kN and TEd = 20 kN·m (cot θ = 2.5).

✔ Shear and torsion verified

Maximum utilisation ratio: 0.70 — governing criterion: links, outer leg (V + T)

VRd,max
537.8 kN
TRd,max
74.0 kN·m
Interaction
0.549
Asw/s required
302 mm²/m

The struts keep a margin (interaction 0.55); the links govern: 236 mm²/m required on the outer leg against 335 mm²/m provided. Torsion also requires 330 mm² of longitudinal bars.

Load this example into the sheet Calculation note of the example (PDF, 3 pages, in French)

300 mm600 mm
Example section, to scale: 4 HA20 tension bars and HA8 links (in colour).
Formulas, limits and references

VRd,s = (Asw/s)·z·fywd·cot θ; VRd,max = αcw·bw·z·ν1·fcd/(cot θ + tan θ)
TEd/TRd,max + VEd/VRd,max ≤ 1 (6.29)

Limits

  • Rectangular or T sections (torsion carried by the web only); vertical links, z = 0.9·d.
  • Not covered: loads near supports, web-flange shear, punching, box sections, prestressing.
  • Additional force ΔFtd and longitudinal torsion bars to be carried into the bending design; fatigue of bridge links flagged, not calculated.

References: EN 1992-1-1 and its French National Annex (§6.2, §6.3, §9.2); EN 1992-2/NA §6.8.1(102); our handbook: sections, buckling and torsion.

Check: example checked by hand.

Frequently asked questions

Which strut angle should I choose?

The larger cot θ, the fewer links are needed, but the struts resist less and the force in the longitudinal bars increases. For a bridge, outside [1; 1.5], link fatigue must be checked.

How do shear and torsion links add up?

On the outer leg: (Asw/s)V/n + At/s, i.e. 140.2 + 96.0 = 236.2 mm²/m in the example. If TEd/TRd,c + VEd/VRd,c ≤ 1 (6.31), the minimum is enough.

What does an axial force change?

Compression increases VRd,c (σcp limited to 0.2·fcd); tension reduces it and narrows the range allowed for cot θ (6.7bNF).

See also

Sheet for preliminary design and routine checks, provided for guidance only: it does not replace a calculation note prepared by an engineer. Found an issue or have a suggestion? Write to us.