All projects

Diagnosis of the Tosny footbridge

Diagnostic de la passerelle de Tosny

Warren truss footbridge over a branch of the Seine: insufficient capacity and closure requested.

The Tosny footbridge carries pedestrians and cyclists over a branch of the Seine. Ageing, it suffers from many pathologies: perforated deck plates, corroded sections, deformed struts and chords, non-compliant parapets.

Full finite element modelling revealed insufficient load capacity, in addition to the poor condition of the structure: its closure was requested.

Characteristics

  • Type: Warren truss girders with verticals at every other node
  • Span: about 22.50 m; usable width: 1.53 m

Photos

  • Diagnosis of the Tosny footbridge – view 1
  • Diagnosis of the Tosny footbridge – view 2
  • Diagnosis of the Tosny footbridge – view 3