All projects

Load capacity of 17 Aisne departmental bridges

Assessment campaign on 17 bridges, often steel and a century old: weight restrictions proposed and urgent works identified.

Under a framework contract, THEOREMS checked the load capacity of seventeen bridges of the Aisne Departmental Council, most of them built between 1921 and 1949. Each study leads to an operational conclusion: weight restriction, urgent works or further investigations.

Structures assessed

StructureBuiltIQOA ratingExisting restrictionConclusion
D0129 – Seraucourt-le-Grand19293U19 tRestriction to 12 t
D0131 – Saint-Simon19413U40 tRestriction to 30 t
D0182 – Marle?3U–No restriction, urgent works
D0231 – Neuvillette?3–No restriction, urgent works
D249A – Iron19233U15 tRestriction to 19 t
D0394 – Lesquielles-Saint-Germain19223U–No restriction, urgent works
D0480 – Neufchâtel19493–19 t pending works, then no restriction
D0493 – Bourg-et-Comin1948––19 t pending works, then no restriction
D0510 – Fontaine-les-Clercs19223U19 tRestriction to 19 t
D0390 – Omissy19253U–Restriction to 12 t
D110D – Pinon19493S–19 t on 2 lanes or 26 t on 1 lane
D0095 – Tavaux-et-Pontséricourt1922 ?2E–19 t pending works, then no restriction
D0459 – Marleafter 19402E–25 t pending works, then no restriction
D0460 – Marle?1–No restriction if arch > 45 cm; investigations required
D0473E19712E–No restriction
D0623 – Origny-Sainte-Benoîte1921––Restriction to 19 t
D0623A19212–Restriction to 19 t